Related Experiment Video
Updated: May 8, 2026

High Content Screening Analysis to Evaluate the Toxicological Effects of Harmful and Potentially Harmful Constituents (HPHC)
Published on: May 10, 2016
PAH-CALUX, an optimized bioassay for AhR-mediated hazard identification of polycyclic aromatic hydrocarbons (PAHs) as
B Pieterse1, E Felzel, R Winter
1BioDetection Systems BV. , Science Park 406. Amsterdam, The Netherlands.
Abstract:
Polycyclic aromatic hydrocarbons (PAHs) represent a class of ubiquitously occurring environmental compounds that are implicated in a wide range of toxicological effects. Routine measurement of PAH contamination generally involves chemical analytical analysis of a selected group of representatives, for example, EPA-16, which may result in underestimation of the PAH-related toxicity of a sample. Many high molecular weight PAHs are known ligands of the aryl hydrocarbon receptor (AhR), a nuclear receptor that mediates toxic effects related to these compounds. Making use of this property we developed a PAH CALUX assay, a mammalian, H4IIe- cell-based reporter assay for the hazard identification of total PAH mixtures. The PAH CALUX reporter cell line allows for specific, rapid (4 h exposure time) and reliable quantification of AhR-induced luciferase induction relative to benzo[a]pyrene (BaP), which is used as a positive reference PAH congener. Full dose response relationships with inductions over 100-fold were reached within only 2 h of exposure to BaP. The PAH CALUX is highly sensitive, that is, using a 4 h exposure time, a limit of detection (LOD) of 5.2 × 10(-11) M BaP was achieved, and highly accurate, that is, a repeatability of 5.9% and a reproducibility of 6.6% were established. Screening of a selection of PAHs that were prioritized by the European Union and/or the U.S. Environmental Protection Agency showed that the PAH CALUX bioassay has a high predictability, particularly for carcinogenic PAHs. Experiments with synthetic mixtures and reference materials containing complex PAH mixtures show the suitability of the assay for these types of applications. Moreover, the presented results suggest that application of the PAH CALUX will result in a lower risk of underestimation of the toxicity of a sample than chemical analytical approaches that focus on a limited set of prioritized compounds.
More Related Videos
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
08:12Characterization, Quantification and Compound-specific Isotopic Analysis of Pyrogenic Carbon Using Benzene Polycarboxylic Acids (BPCA)
Published on: May 16, 2016
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Gas Chromatography: Types of Detectors-II