[A SEM evaluation of the surface color of Dicor crowns]
F Fraccari1, R Cocchetto, A Sbarbati
1Instituto di Clinica Odontoiatrica, Università degli Studi di Verona.
Minerva Stomatologica
|June 1, 1990
Abstract:
With multiple measurements on Dicor crowns cast on extracted teeth and observed under SEM, we determined that the thickness of the external layer of shading porcelain has a mean value of 55 +/- 12 microns (for 4 applications). This datum must be considered so that a dimensional error is not introduced in the construction of these types of crowns.