Evaluation of Drug Sorption to PVC- and Non-PVC-based Tubes in Administration Sets Using a Pump
Published on: March 11, 2017
Stability of Lorazepam in 5% dextrose injection
Lorazepam adsorption onto polyvinyl chloride (PVC) bags is significant, but spectrophotometric methods overestimate drug loss. High-performance liquid chromatography (HPLC) accurately quantifies lorazepam loss, accounting for preservative interference.
Area of Science:
- Pharmaceutical Sciences
- Analytical Chemistry
- Drug Delivery Systems
Background:
- Intravenous admixtures are susceptible to drug adsorption onto storage containers.
- Polyvinyl chloride (PVC) bags are commonly used for parenteral drug storage.
- Accurate quantification of drug loss is crucial for therapeutic efficacy and patient safety.
Purpose of the Study:
- To investigate the adsorption of lorazepam in intravenous admixtures onto 50-mL PVC bags.
- To compare the accuracy of a spectrophotometric assay method with a newly developed high-performance liquid chromatography (HPLC) method for quantifying lorazepam loss.
- To identify factors contributing to discrepancies in measured drug loss.
Main Methods:
- Adsorption of lorazepam in intravenous admixtures onto 50-mL PVC bags was studied.
- Drug concentrations were measured using a literature-reported spectrophotometric assay.
- A novel HPLC assay method was developed and employed for comparative analysis.
- Adsorption kinetics and the effect of admixture volume were evaluated.
Main Results:
- The spectrophotometric method indicated a lorazepam loss of 7.7%–9.5%.
- The HPLC method revealed a significantly lower lorazepam loss of 4.9%–5.5%.
- Benzyl alcohol, a preservative in lorazepam injection, interfered with the spectrophotometric assay, causing overestimation of drug loss.
- Adsorption of lorazepam occurred within six hours, with no further significant loss thereafter.
- Varying admixture volumes (20–50 mL) did not significantly alter the extent of drug loss due to adsorption.
Conclusions:
- The spectrophotometric assay overestimates lorazepam loss due to interference from benzyl alcohol.
- HPLC is a more accurate method for quantifying lorazepam adsorption onto PVC bags.
- Understanding drug-container interactions is essential for ensuring accurate dosing of intravenous medications.
Related Concept Videos
Drug Product Stability
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Nonlinear Pharmacokinetics: Drug Elimination for IV Bolus Injection
Following the administration of a single intravenous (IV) bolus injection, we can determine the concentration of the drug in the plasma at any given time. This calculation is achieved using a specific equation that integrates the values of Vmax and KM.
We can also...
Sedatives and Hypnotics Drugs: Benzodiazepines
Benzodiazepines work by enhancing the effects of the inhibitory neurotransmitter GABA. They bind to the GABAA receptor, increasing its affinity for GABA, which opens chloride...
Local Anesthetics: Pharmacokinetics
Drug Accumulation During Multiple Dosing: Repetitive IV Injections