What's in your buffer? Solute altered millisecond motions detected by solution NMR

Madeline Wong1, Gennady Khirich, J Patrick Loria

  • 1Department of Chemistry and ‡Department of Molecular Biophysics and Biochemistry, Yale University , New Haven, Connecticut 06520, United States.

Biochemistry
|September 3, 2013
PubMed

Related Concept Videos

Chemical Shift: Internal References and Solvent Effects01:17

Chemical Shift: Internal References and Solvent Effects

In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Buffers02:56

Buffers

A solution containing appreciable amounts of a weak conjugate acid-base pair is called a buffer solution, or a buffer. Buffer solutions resist a change in pH when small amounts of a strong acid or a strong base are added. A solution of acetic acid and sodium acetate is an example of a buffer that consists of a weak acid and its salt: CH3COOH (aq) + CH3COONa (aq). An example of a buffer that consists of a weak base and its salt is a solution of ammonia and ammonium chloride: NH3 (aq) + NH4Cl...
Buffers: Overview01:30

Buffers: Overview

Buffers play a crucial role in stabilizing the pH of a solution by mitigating the effects of small amounts of added acid or base. They consist of a weak acid and its conjugate base or a weak base and its conjugate acid. A solution of acetic acid and sodium acetate is an example of a buffer that consists of a weak acid and its salt: CH3COOH (aq) + CH3COONa (aq). An example of a buffer that consists of a weak base and its salt is a solution of ammonia and ammonium chloride: NH3 (aq) + NH4Cl (aq).
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
NMR Spectroscopy: Chemical Shift Overview01:15

NMR Spectroscopy: Chemical Shift Overview

The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
Buffer Systems in the Body01:19

Buffer Systems in the Body

Chemical buffers play a critical role in the body's regulation of pH levels. These systems contain one or more compounds that stabilize pH changes by neutralizing strong acids or bases. When pH levels drop, hydrogen ions bind to a weak base; when pH levels rise, hydrogen ions are released. This dynamic process helps maintain pH within a narrow and stable range essential for normal physiological function.
A typical buffer system in bodily fluids includes a weak acid and its corresponding anion,...