Coherent anti-Stokes Raman Scattering (CARS) Microscopy Visualizes Pharmaceutical Tablets During Dissolution
Published on: July 4, 2014
In situ dissolution analysis using coherent anti-Stokes Raman scattering (CARS) and hyperspectral CARS microscopy
Andrew Fussell1, Erik Garbacik, Herman Offerhaus
1Optical Sciences Group, Faculty of Science and Technology, MESA+ Institute of Nanotechnology, University of Twente, Enschede, The Netherlands.
Abstract:
The solid-state form of an active pharmaceutical ingredient (API) in an oral dosage form plays an important role in determining the dissolution rate of the API. As the solid-state form can change during dissolution, there is a need to monitor the oral dosage form during dissolution testing. Coherent anti-Stokes Raman scattering (CARS) microscopy provides rapid, spectrally selective imaging to monitor the oral dosage form during dissolution. In this study, in situ CARS microscopy was combined with inline UV absorption spectroscopy to monitor the solid-state change in oral dosage forms containing theophylline anhydrate undergoing dissolution and to correlate the solid-state change with a change in dissolution rate. The results from in situ CARS microscopy showed that theophylline anhydrate converted to theophylline monohydrate during dissolution resulting in a reduction in the dissolution rate. The addition of methyl cellulose to the dissolution medium was found to delay the theophylline monohydrate growth and changed the morphology of the monohydrate. The net effect was an increased dissolution rate for theophylline anhydrate. Our results show that in situ CARS microscopy combined with inline UV absorption spectroscopy is capable of monitoring oral dosage forms undergoing dissolution and correlating changes in solid-state form with changes in dissolution rate.
More Related Videos
12:56Differential Imaging of Biological Structures with Doubly-resonant Coherent Anti-stokes Raman Scattering (CARS)
Published on: October 17, 2010
12:54Implementation of a Coherent Anti-Stokes Raman Scattering (CARS) System on a Ti:Sapphire and OPO Laser Based Standard Laser Scanning Microscope
Published on: July 17, 2016
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Spectroscopy of Carboxylic Acid Derivatives
In the...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...