E M Fallenberg1, L Dimitrijevic2, F Diekmann3
1Clinic of Radiology, Campus Virchow-Klinikum, Charité - Universitätsmedizin, Berlin.
Purpose:
To evaluate the additional benefit of true geometric (air-gap) magnification views for the characterization of microcalcifications in digital mammography.
Materials And Methods:
After ethical approval, we retrospectively reviewed patient records to identify 100 patients with suspicious microcalcifications (35 malignant, 65 benign) who had a standard digital mammography and an additional digital magnification view in the same projection within three months. All images were obtained using an amorphous silicon-based full-field digital system (Senographe 2000 D, GE Healthcare, Chalfont St. Giles, UK). Images were independently analyzed by six board-certified radiologists. The probability of malignancy was estimated using first standard contact mammography alone (MG) and then mammography in combination with the magnification view (MG+MAG) using a modified Breast Imaging Reporting and Data System (BI-RADS) classification system and a percentage scale. Results were compared using receiver operating characteristic (ROC) analysis. In addition, readers assessed the subjective visibility of the calcifications.
Results:
For all six readers combined, the area under the curve (AUC) was 0.664 ± 0.052 for MG and 0.813 ± 0.042 for MG + MAG, resulting in a statistically significant improvement of 0.148 ± 0.120. Each reader had a higher AUC for MG + MAG than MG, with the improvement being statistically significant in four of the six readers. In 76.34 % of the cases, MG + MAG resulted in better visibility of calcifications compared with mammography alone. In 33 % slightly more and in 39 % significantly more calcifications were found.
Conclusion:
Even in digital mammography with the option of using electronic magnification (zoom) at the viewing workstation, true geometric (air-gap) magnification views remain important for the visibility and correct classification of microcalcifications and for the assessment of their extent.
Related Concept Videos
Overview of Microscopy Techniques
Three-Dimensional Microscopy in Microbiology
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...