Development and validation of an analytical method for quantification of arsenic and antimony in liposomes using
Priscila G Reis1, Adriana T Abreu, Andrea G Guimarães
1Universidade Federal de Ouro Preto, Departamento de Farmicía, Ouro Preto, Minas Gerais, Brazil.
Abstract:
Arsenic and antimony compounds are used to treat endemic diseases, such as cancer, leishmaniasis, and schistosomiasis, in spite of their toxicity. Several studies seeking the development and characterization of nanocarrier systems such as liposomes are being carried out with the aim of developing new drug delivery systems and minimizing the toxicity of these drugs. However, the lack of reference methods to quantify these semimetals within a liposomal matrix hinders the QC of these formulations. Therefore, the validation of an analytical method for arsenic and antimony quantification in liposomal matrix by inductively coupled plasma-optical emission spectrometry is presented here. The linearity, specificity, LOD, LOQ, accuracy, and precision were determined according to the International Conference on Harmonization norms and the Brazilian Health Surveillance Agency (Resolution 899). The LOD values were 0.02 and 0.06 mg/L for antimony and arsenic, respectively. The LOQ for both was 3.0 mg/L, with an adequate accuracy within 98.26 and 101.32% for different levels of antimony and 99.98 and 100.36% for arsenic. Precision (CV) was lower than 5.0%. The developed and validated method was shown to be reproducible for quantification of arsenic and antimony in liposome pharmaceutical dosage forms.
More Related Videos
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
09:12A Quantitative Fluorescence Microscopy-based Single Liposome Assay for Detecting the Compositional Inhomogeneity Between Individual Liposomes
Published on: December 13, 2019
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.