A perspective demonstration on the importance of variable selection in inverse calibration for complex analytical
Yong-Huan Yun1, Yi-Zeng Liang, Gui-Xiang Xie
1College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, P. R. China. yizeng_liang@263.net.
Abstract:
Classical calibration and inverse calibration are two kinds of multivariate calibration in chemical modeling. They use strategies of modeling in component spectral space and in measured variable space, respectively. However, the intrinsic difference between these two calibration models is not fully investigated. Besides, in the case of complex analytical systems, the net analyte signal (NAS) cannot be well defined in inverse calibration due to the existence of uninformative and/or interfering variables. Therefore, application of the NAS cannot improve the predictive performance for this kind of calibration, since it is essentially a technique based on the full-spectrum. From our perspective, variable selection can significantly improve the predictive performance through removing uninformative and/or interfering variables. Although the need for variable selection in the inverse calibration model has already been experimentally demonstrated, it has not aroused so much attention. In this study, we first clarify the intrinsic difference between these two calibration models and then use a new perspective to intrinsically prove the importance of variable selection in the inverse calibration model for complex analytical systems. In addition, we have experimentally validated our viewpoint through the use of one UV dataset and two generated near infrared (NIR) datasets.
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Multi-input and Multi-variable systems
In the absence of...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Correlation Coefficient
Derivatives of Inverse Trigonometric Functions
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...