Reference electrodes with salt bridges contained in nanoporous glass: an underappreciated source of error

Maral P S Mousavi1, Philippe Bühlmann

  • 1Department of Chemistry, University of Minnesota , 207 Pleasant Street South East, Minneapolis, Minnesota 55455, United States.

Analytical Chemistry
|September 6, 2013
PubMed

Related Concept Videos

Potentiometry: Types of Electrodes01:19

Potentiometry: Types of Electrodes

Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Junction Potentials in Galvanic Cells01:21

Junction Potentials in Galvanic Cells

The Nernst equation, derived under the assumption of thermodynamic equilibrium, calculates the electromotive force (emf) as the sum of potential differences at phase boundaries in a reversible cell without a liquid junction. However, in irreversible cells such as the Daniell cell, an additional potential difference named the liquid-junction potential (EJ) arises across the interface of two electrolyte solutions due to different ion diffusion rates. This EJ represents the potential difference...
Potentiometry: Overview01:06

Potentiometry: Overview

Potentiometry is an analytical technique that measures the potential difference between two electrodes in an electrochemical cell without drawing any significant current that could alter the solution's composition. This method employs an indicator electrode, which exchanges electrons with the analyte solution, and a reference electrode with a constant potential. Each electrode is immersed in a solution comprised of two half-cells. In a conventional setup, the reference electrode serves as the...
Types of Reversible Electrodes01:24

Types of Reversible Electrodes

For electrode reversibility to be maintained, all the reactants and products involved in the half-reaction must be present at the electrode. There are several types of reversible electrodes (half-cells).In metal-metal-ion electrodes, a metal balances electrochemically with a solution of its own ions. Examples are Cu2+|Cu and Zn2+|Zn. Metals that react with the solvent, like group 1 and most group 2 metals, which react with water, and zinc, which reacts with aqueous acidic solutions, cannot be...