Wall current probe: a non-invasive in situ plasma diagnostic for space and time resolved current density distribution

R Baude1, F Gaboriau, G J M Hagelaar

  • 1Université de Toulouse, UPS, INPT, LAPLACE (Laboratoire Plasma et Conversion d'énergie), 118 route de Narbonne, F-31062 Toulouse Cedex 9, France and CNRS, LAPLACE, F-31062, Toulouse, France.

Related Concept Videos

Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
Current Density01:21

Current Density

The total amount of current flowing through one unit value of a cross-sectional area is referred to as current density. If the current flow is uniform, the amount of current flowing through a conductor is the same at all points along the conductor, even if the conductor area varies. The current density consists of the local magnitude and direction of the charge flow, which varies from point to point. Current density is measured in amperes per meter square, and direction is defined as the net...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
The Hall Effect01:30

The Hall Effect

Edwin H. Hall, in the year 1879, devised an experiment that could be used to identify the polarity of the predominant charge carriers in a conducting material. From a historical perspective, this experiment was the first to demonstrate that the charge carriers in most metals are negative.
Coulometry: Overview01:00

Coulometry: Overview

Coulometry is one of the rapid, most accurate, and precise analytical techniques that determine the quantity of an analyte by measuring the electrical charge needed for its complete electrolysis without using any analytical standards. The total charge passed during electrolysis correlates with the analyte amount by Faraday's laws of electrolysis. For accurate coulometric measurements, a charge equal to Faraday's constant multiplied by the number of electrons involved in the relevant...
Boundary Conditions for Current Density01:25

Boundary Conditions for Current Density

Current density becomes discontinuous across an interface of materials with different electrical conductivities. The normal component of the current density is continuous across the boundary.