Intermediate follow-up results from the multicenter engager European pivotal trial
David Holzhey1, Axel Linke, Hendrik Treede
1Department of Cardiovascular Surgery and Department of Internal Medicine/Cardiology, Heart Center Leipzig, Leipzig, Germany.
Background:
Optimal transcatheter aortic valve (TAVI) results require accurate valve positioning, including anatomically correct orientation and secure fixation within the aortic annulus, thereby potentially decreasing paravalvular regurgitation. The new Engager (Medtronic 3F Therapeutics, Santa Ana, CA) transapical valve system captures the native leaflets for sealing and allows for tactile feedback during valve placement. We report initial safety and performance outcomes of the Engager system through 6 months in patients with severe aortic valve stenosis at high risk for surgical aortic valve replacement.
Methods:
An interim analysis was performed on the first 61 enrolled September 2011 through May 2012. Inclusion criteria comprised severe aortic stenosis, New York Heart Association functional class of II or greater, logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) of 20% or greater, or contraindication to surgical aortic valve replacement. The primary endpoint was all-cause mortality at 30 days. Patients were evaluated 24 to 48 hours post-procedure, at hospital discharge, 30 days and 6 months. Follow-up is planned annually through five years.
Results:
Baseline characteristics for the 61 patients were mean age 81.9 ± 4.4 years, 62.3% female, 88.5% New York Heart Association class III/IV, 52.5% coronary artery disease, and 54.2% extracardiac arteriopathy. For all of the attempted implantations (n = 60), the Engager prosthesis was positioned in the correct anatomic position without conversions to surgery, second valve implantation, device malposition, aortic annular rupture, or coronary obstruction. All-cause mortality was 9.9% at 30 days and 16.9% at 6 months. The baseline mean aortic valve gradient was 43.7 ± 16.7 mm Hg and 11.5 ± 5.0 mm Hg at 30 days, and showed similar reduction at 6 months (13.9 ± 6.2 mm Hg). There was no paravalvular regurgitation greater than mild through 6 months.
Conclusions:
Early postoperative results support implantation success and valve safety. Analysis for 6 month outcomes shows stable hemodynamic performance and clinical outcome. (Transapical Implantation of the Medtronic Engager Transcatheter Aortic Valve Implantation System-the Engager European Pivotal Trial; NCT01348438).
More Related Videos
06:28E-Patient Counseling Trial (E-PACO): Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
04:53A Clinical Trial Assessing the Safety, Efficacy, and Delivery of Olive-Oil-Based Three-Chamber Bags for Parenteral Nutrition
Published on: September 20, 2019
Related Concept Videos
Clinical Trials: Overview
Clinical Trials
There are four phases in a clinical trial. A phase one...
Bioavailability Study Design: Healthy Subjects Versus Patients
Preclinical Development: Overview
Treatment for Pulmonary Arterial Hypertension: Endothelin Receptor Antagonists
ETs are synthesized through a complex sequence of enzymatic steps, primarily involving an enzyme referred to as endothelin-converting enzyme (ECE). Of...
Bioavailability Study Design: Single Versus Multiple Dose Studies