Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Dolichocarotids: echo-color Doppler evaluation and clinical role
Marco Matteo Ciccone1, Rakesh K Sharma, Pietro Scicchitano
1Cardiology Unit, Emergency and Organ Transplantation Department(DETO), University of Bari.
Dolichocarotids (DCs) are rare carotid findings. Echo-color Doppler (ECD) accurately detects DCs, with kinking associated with cardiovascular death, highlighting ECD
Area of Science:
- Vascular Imaging
- Cerebrovascular Diseases
- Diagnostic Accuracy
Background:
- Dolichocarotids (DCs) are uncommon carotid artery elongations, found in 2-6% of the population.
- DCs may be asymptomatic or linked to cerebrovascular events.
- Carotid echo-color Doppler (ECD) and selective angiography are standard detection methods.
Purpose of the Study:
- To assess the sensitivity, specificity, and accuracy of ECD in detecting DCs.
- To monitor DC curvature changes over five years.
- To evaluate the association of DCs with TIA, ischemic stroke, myocardial infarction, and cardiovascular death.
Main Methods:
- 112 patients with DCs underwent carotid ECD and angiography.
- Patients had persistent neurological symptoms unexplained by initial ultrasound.
- Follow-up extended to five years.
Main Results:
- ECD demonstrated 100% sensitivity for tortuosity/coiling and 96% for kinking.
- Overall ECD accuracy ranged from 92% to 100%.
- Significant increases in tortuosity and kinking angles were observed over five years; kinking correlated with cardiovascular death.
Conclusions:
- DCs increase the risk of disabling and fatal cerebrovascular events.
- ECD is a reliable and reproducible method for DC detection.
- ECD plays a crucial role in managing patients with dolichocarotids.
More Related Videos
04:01Point of Care Transcranial Color-Coded Duplex Ultrasound of the Middle Cerebral Artery
Published on: August 9, 2024
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Mitral Regurgitation II: Clinical Features and Diagnostic Tests