Related Experiment Video
Updated: May 8, 2026

Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
Reproducibility in echocardiographic two- and three-dimensional mitral valve assessment
Maximilian Dominik Hien1, Manuel Großgasteiger, Alexander Weymann
1Department of Anesthesiology, University of Heidelberg, Heidelberg, Germany; Department of Pediatrics, University of Heidelberg, Heidelberg, Germany; Research Training Group 1126, German Research Foundation (DFG), Bonn, Germany.
Background:
Three-dimensional transesophageal echocardiography (3DTEE) has been demonstrated to provide more accurate information than two-dimensional transesophageal echocardiography (2DTEE) in the localization of mitral valve prolapse (MVP). However, most studies have been single-rater studies. Few results were tested for inter-observer variability with a single second rater. This multicenter study aimed to determine reliability of 2D and 3DTEE mitral valve evaluations by calculating inter-observer agreement between various echocardiographers.
Methods:
Fifteen observers from 4 institutions in Germany and Switzerland interpreted 2D and 3DTEE images from 6 patients selected to represent a large spectrum of MVP diversity. Surgical findings served as reference. Individual assessments of MVP and ruptured chordae tendineae (ChR) pathology were compared by calculating Randolph's free-marginal multirater kappa coefficient.
Results:
Accuracy of MVP evaluation with 3DTEE was 83.9%, CI [81.0%; 86.8%] and 78.7% CI [76.6% 80.8%] with 2DTEE. Flail leaflets with chordal ruptures were described correctly in 91.1%, CI [85.8, 96.4] with 3D compared to 71.1%, CI [65.0, 77.2] with 2DTEE. The multirater kappa coefficient of inter-observer agreement among all 15 observers was κ = 0.65/0.58 for 3D/2D evaluation of MVP and κ = 0.70/0.54 for detection of ChR.
Conclusion:
Three-dimensional assessment of MVP was superior to 2DTEE, although the accuracy of both 3DTEE and 2DTEE was found to be lower than previously published. 3D MVP assessment is less operator dependent than 2DTEE evaluation. Although validity has been demonstrated before, we provide evidence that 3DTEE is reproducible among 15 observers and is a reliable method for MVP evaluation.