Related Experiment Video
Updated: May 7, 2026

Resolving Water, Proteins, and Lipids from In Vivo Confocal Raman Spectra of Stratum Corneum through a Chemometric Approach
Published on: September 26, 2019
Resolution of five-component mixture using mean centering ratio and inverse least squares chemometrics
Mahmoud Mohamed Issa1, R'afat Mahmoud Nejem, Alaa Mohamed Abu Shanab
1Analytical Chemistry, Department of Chemistry, Alaqsa University, P,O,Box 4051, Gaza, Palestine. rafat_nejem@yahoo.com.
Background:
A comparative study of the use of mean centering of ratio spectra and inverse least squares for the resolution of paracetamol, methylparaben, propylparaben, chlorpheniramine maleate and pseudoephedrine hydrochloride has been achieved showing that the two chemometric methods provide a good example of the high resolving power of these techniques. Method (I) is the mean centering of ratio spectra which depends on using the mean centered ratio spectra in four successive steps that eliminates the derivative steps and therefore the signal to noise ratio is improved. The absorption spectra of prepared solutions were measured in the range of 220-280 nm. Method (II) is based on the inverse least squares that depend on updating developed multivariate calibration model. The absorption spectra of the prepared mixtures in the range 230-270 nm were recorded.
Results:
The linear concentration ranges were 0-25.6, 0-15.0, 0-15.0, 0-45.0 and 0-100.0 μg mL-1 for paracetamol, methylparaben, propylparaben, chlorpheniramine maleate and pseudoephedrine hydrochloride, respectively. The mean recoveries for simultaneous determination were between 99.9-101.3% for the two methods. The two developed methods have been successfully used for prediction of five-component mixture in Decamol Flu syrup with good selectivity, high sensitivity and extremely low detection limit.
Conclusion:
No published method has been reported for simultaneous determination of the five components of this mixture so that the results of the mean centering of ratio spectra method were compared with those of the proposed inverse least squares method. Statistical comparison was performed using t-test and F-ratio at P = 0.05. There was no significant difference between the results.
Related Concept Videos
Racemic Mixtures and the Resolution of Enantiomers
High-Resolution Mass Spectrometry (HRMS)
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
¹H NMR Signal Integration: Overview
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Classification of Titrimetric Analysis Based on Reaction Types
Titrations between an acid and a base lead to neutralization reactions that form...