Can ulnar variance be used to detect overstuffing after radial head arthroplasty?
Jun-Gyu Moon1, Jin-Ho Hong, Nitin Bither
1Department of Orthopedic Surgery, Korea University Guro Hospital, 97 Gurodong-gil, Guro-gu, Seoul, 152-703, Korea, moon@korea.ac.kr.
Background:
Overstuffing of the radiocapitellar joint during metallic radial head arthroplasty has been reported to cause loss of elbow flexion, capitellar erosion, and early-onset osteoarthritis. Although this is known, there is no agreed-on measurement approach to determine whether overstuffing has occurred.
Questions/Purposes:
We therefore hypothesized that overlengthening the radial head during radial head arthroplasty changes the ulnar variance in the wrist.
Methods:
Seven cadaveric radii were implanted with radial head prostheses of increasing thickness. Each specimen was implanted successively with increasingly thick radial head prostheses measuring 2, 4, and 6 mm thicker than the native radial head, and radiographs were taken after implantation of each prosthesis. The ulnar variance with each prosthesis was measured using the method of perpendiculars.
Results:
The ulnar variance of the native and 2-mm (p = 0.04), 4-mm (p = 0.008), and 6-mm (p = 0.008) overly thick radial head prosthesis-implanted states decreased significantly with each incremental increase in prosthetic head thickness.
Conclusions:
Implantation of thicker radial head prostheses decreased the ulnar variance. Our results indicate ulnar variance could be used to detect overstuffing of radial head prostheses.
Clinical Relevance:
The simplicity and reliability of ulnar variance make it a potentially useful indicator of overlengthening after radial head arthroplasty.
Related Concept Videos
Bones of the Upper Limb: Ulna
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a short...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...