Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Residuals and Least-Squares Property01:11

Residuals and Least-Squares Property

The vertical distance between the actual value of y and the estimated value of y. In other words, it measures the vertical distance between the actual data point and the predicted point on the line
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Reduced Mass Coordinates: Isolated Two-body Problem01:12

Reduced Mass Coordinates: Isolated Two-body Problem

In classical mechanics, the two-body problem is one of the fundamental problems describing the motion of two interacting bodies under gravity or any other central force. When considering the motion of two bodies, one of the most important concepts is the reduced mass coordinates, a quantity that allows the two-body problem to be solved like a single-body problem. In these circumstances, it is assumed that a single body with reduced mass revolves around another body fixed in a position with an...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Generation and characterization of a novel human IgG1 antibody against vascular endothelial growth factor receptor 2.

Cancer immunology, immunotherapy : CII·2014
Same author

ERK1/2-Egr-1 Signaling Pathway-Mediated Protective Effects of Electroacupuncture in a Mouse Model of Myocardial Ischemia-Reperfusion.

Evidence-based complementary and alternative medicine : eCAM·2014
Same author

The effect of transcutaneous electrical acupoint stimulation on pregnancy rates in women undergoing in vitro fertilization: a study protocol for a randomized controlled trial.

Trials·2014
Same author

Hypertension prevalence, awareness, treatment, and control and sodium intake in Shandong Province, China: baseline results from Shandong-Ministry of Health Action on Salt Reduction and Hypertension (SMASH), 2011.

Preventing chronic disease·2014
Same author

A novel electrochemical method to determine α-amylase activity.

The Analyst·2014
Same author

The inhibitor of calcium/calmodulin-dependent protein kinase II KN93 attenuates bone cancer pain via inhibition of KIF17/NR2B trafficking in mice.

Pharmacology, biochemistry, and behavior·2014
Same journal

Rapid personalisation of cardiovascular models using invasively measured right ventricular pressure.

Computers in biology and medicine·2026
Same journal

Biologically inspired mechanisms for enhancing robustness in EEG signal modeling: Challenges, opportunities, and perspectives.

Computers in biology and medicine·2026
Same journal

Machine learning-based detection of missed inspiratory efforts using esophageal pressure during noisy pressure support ventilation.

Computers in biology and medicine·2026
Same journal

A computational model of chemically- and mechanically-induced thrombus formation in cerebral aneurysms.

Computers in biology and medicine·2026
Same journal

An improved catch fish optimization based deep learning model for Parkinson disease classification using EEG signal.

Computers in biology and medicine·2026
Same journal

Assessing the robustness of evaluation metrics for synthetic ECG signal quality.

Computers in biology and medicine·2026
See all related articles

Related Experiment Video

Updated: May 7, 2026

Multimodal Cross-Device and Marker-Free Co-Registration of Preclinical Imaging Modalities
07:13

Multimodal Cross-Device and Marker-Free Co-Registration of Preclinical Imaging Modalities

Published on: October 27, 2023

Intensity based image registration by minimizing exponential function weighted residual complexity.

Juan Zhang1, Zhen-Tai Lu, Vadim Pigrish

  • 1School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China.

Computers in Biology and Medicine
|September 17, 2013
PubMed
Summary
This summary is machine-generated.

This study introduces a new intensity-based method for medical image registration, improving accuracy and robustness against distortions. The novel approach enhances image alignment for better diagnostic insights.

Keywords:
Exponential functionIntensity distortionLocal varianceResidual complexityWeighting function

More Related Videos

Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
02:09

Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function

Published on: April 12, 2024

Related Experiment Videos

Last Updated: May 7, 2026

Multimodal Cross-Device and Marker-Free Co-Registration of Preclinical Imaging Modalities
07:13

Multimodal Cross-Device and Marker-Free Co-Registration of Preclinical Imaging Modalities

Published on: October 27, 2023

Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
02:09

Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function

Published on: April 12, 2024

Area of Science:

  • Medical Imaging
  • Image Processing
  • Computer Vision

Background:

  • Traditional intensity-based medical image registration methods struggle with intensity distortions, contrast agents, and noise.
  • Existing techniques like residual complexity can be sensitive to parameter modifications, leading to inconsistent results.

Purpose of the Study:

  • To develop a novel, robust intensity-based similarity measure for accurate medical image registration.
  • To overcome limitations of traditional methods by introducing an adaptive weighting mechanism.

Main Methods:

  • A novel similarity measure incorporating an exponential weighting function applied to the residual term.
  • The weighting function is modeled using the local variance of the reference image.
  • The method was tested on brain MRI, breast DCE-MRI, and liver CT datasets.

Main Results:

  • The proposed method demonstrated superior accuracy and robustness compared to mutual information, residual complexity, and Jensen-Tsallis.
  • Effective performance was observed across diverse medical imaging modalities, including MRI and CT.
  • Automatic weighting of residual images improved registration outcomes.

Conclusions:

  • The novel exponential weighting-based similarity measure offers a significant advancement in medical image registration.
  • The technique provides more accurate and reliable image alignment, particularly in the presence of image artifacts.
  • This approach enhances the utility of medical image registration for clinical applications.