Background:
The radial artery is the most common site for arterial cannulation. Procedures for improving radial artery cannulation have involved direct visualization of the vessel with ultrasonography (US). The aim of this study evaluate the short axis and long axis radial artery measurements at 0º, 45º, 60º wrist joint angle and find out the optimal wrist joint angle for long and short axis US guided radial artery cannulation.
Materials And Methods:
This study was approved by the Institutional Ethical Committee and the study was performed in accordance with the ethical principles for human investigations, as outlined by the Second Declaration of Helsinki. One hundred fifty-two (90 men and 62 women, 18-48 years of age, mean age: 32.9 ± 6.1) healthy volunteers were recruited. The radial artery distance between skin and height, width, area in short axis and radial artery distance between skin and height was measured in long axis at 0º, 45º, 60º wrist joint angle were measured. Results. Short axis radial artery distance between skin, width, height, area and long axis radial artery distance between skin, height were statistically significantly different among 0º, 45º, 60º (p< 0.05; for all comparisons). Short axis width was statistically significantly increased at 45º compared to at 0º (p< 0.001;). Short axis radial artery distance between skin and height at 45º were statistically significantly decreased than at 0º (p< 0.001; for all comparisons) and long axis skin distance and height at 45º were also statistically significantly decreased than at 0º (p< 0.001; for both comparisons). Short axis radial artery skin distance and area at 60º is statistically significantly decreased than at 45º (p< 0.001; for both comparisons) and also long axis height of radial artery at 60º is statistically significantly decreased than at 45º (p< 0.001;).
Conclusions:
Angle increment up to 45º might help clinicians for radial artery cannulation in short axis plane whereas this angle increment maneuver decreased the arterial height in long axis which might be a potential disadvantage for cannulation.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Arteries of the Upper Limbs
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a short...
Pre-Procedural Guidelines for Assessing Blood Pressure
Bones of the Upper Limb: Ulna