Related Experiment Video
Updated: May 7, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Do routine radiographs within the first two years following pediatric posterior spinal fusion prompt revision
Grant H Garcia1, Min Jung Park, Keith Baldwin
1*The Hospital for Special Surgery, New York, NY †Hospital of the University of Pennsylvania, Philadelphia, PA; and ‡The Children's Hospital of Philadelphia, Philadelphia, PA.
Study Design:
This is a retrospective review of 265 consecutive patients with scoliosis treated by posterior spinal fusion (PSF) and 2990 postoperative radiographs at a single institution.
Objective:
To document implant-related complications on postoperative radiographs within the first 2 years after PSF and determine if these led to additional surgical procedures.
Summary Of Background Data:
To date, there is an absence of studies investing the utility of radiographs after pediatric PSF surgery.
Methods:
The patient's average age was 14.9 years (8.2-21.8 yr). Positive radiographical findings included implant loosening, fracture, migration, or loss of fixation. We also noted which patients' required additional surgery for a radiographical finding and/or clinical finding (neurological deficit, intractable back pain, fever, and elevated erythrocyte sedimentation rate, c-reactive protein, or while blood cell count).
Results:
At an average follow-up of 16.3 months (12-24), only 18 (0.60%) radiographs demonstrated a positive finding. Of these, only 5 (0.17%) radiographs (along with clinical presentation) prompted revision. No patient returned to the operating room purely from a radiographical finding. The remaining 13 (0.37%) abnormal plain images were not associated with a clinical abnormality and were managed nonoperatively. The timing of the second operation was in the range from 1 day to 23 months (average, 11 mo). Postoperative plain radiographs had a sensitivity of 26.5%, a specificity of 99.5%, and a positive predictive value of 25%.
Conclusion:
Only 0.60% of postoperative images (18/2990) demonstrated an implant-related complication, and in the absence of clinical indications, none of these patients required surgical intervention. Isolated postoperative radiographs did not lead to any change in management, and consideration should be given to reviewing current protocols for plain radiographs as a monitoring tool after PSF.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...