Efficacy of exogenous surfactant during conventional and high-frequency oscillatory ventilation in preterm infants
Giovanni Vento1, Milena Tana, Chiara Tirone
1Department of Pediatrics, Division of Neonatology, Università Cattolica del Sacro Cuore, Rome, Italy. vento@rm.unicatt.it
Introduction:
The immediate effects of exogenous surfactant on lung volume and hemodynamics in preterm infants have been poorly studied.
Materials And Methods:
Lung volume, SpO2, perfusion index, regional SO2, transcutaneous partial pressure of CO2 were simultaneously monitored and recorded ten minutes after surfactant tracheal instillation in elective HFOV ventilated preterm infants with RDS.
Outcomes:
Despite a reduction in gas exchange during the first 5 minutes post surfactant instillation, most likely dependent on airway obstruction, lung volume increases rapidly in HFOV preterm infants with RDS. After 5 minutes from administration of surfactant, lung volume, gas exchange and PI reach stable values and CDP can be safely reduced.
Related Concept Videos
Breathing
Pulmonary Cycle: Exhalation
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation I: Indication and Settings