[Changes in arterial uterine blood flow velocity waveform during uterine contraction and relaxation in labor]

Y Takeuchi1

  • 1Department of Obstetrics and Gynecology, Tottori University School of Medicine, Yonago.

The arterial uterine blood flow velocity waveform during uterine contraction and relaxation in labor was measured with ultrasonic continuous wave (CW) Doppler device in 44 pregnant women at 37-41 weeks of gestation. The fetal heart rate (FHR) was also recorded by cardiotocogram during labor in every case. 1. Both the resistance index (RI) and pulsatility index (PI) of the arterial uterine blood flow velocity waveform were significantly higher during uterine contraction than during relaxation (p less than 0.005). These increases in RI and PI during contraction were not influenced by the maternal heart rate. The reverse or interrupted end-diastolic flow was demonstrated in 16.3% of the cases. 2. No abnormal FHR patterns were observed in any of the cases except two with early deceleration or mild variable deceleration in which uterine arterial end-diastolic flow was maintained. The fetal conditions did not seem to be influenced by the reduction of arterial uterine blood flow in our study.

Related Concept Videos

Pulse01:16

Pulse

When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical indicator...
Autoregulation of Blood Flow01:17

Autoregulation of Blood Flow

Autoregulation mechanisms are characterized by their inherent capacity for self-regulation without necessitating specific nervous stimulation or endocrine control. These mechanisms facilitate the adjustment of blood flow and, therefore, perfusion specific to each tissue region. This self-regulation encompasses chemical signals and myogenic controls.
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Urodynamic Studies: Uroflowmetry01:19

Urodynamic Studies: Uroflowmetry

Uroflowmetry is a non-invasive urodynamic test designed to measure various aspects of urination, including volume, flow rate, and the time to void. This test is crucial for diagnosing and assessing conditions such as bladder outlet obstruction, bladder dysfunction, incomplete bladder emptying, incontinence, and urinary tract blockages caused by benign prostatic hyperplasia (BPH) and urethral strictures.Pre-Test Instructions:Before a uroflowmetry test, patients are typically advised to drink...