Related Experiment Video
Updated: May 7, 2026

Technical Refinement of a Bilateral Renal Ischemia-Reperfusion Mouse Model for Acute Kidney Injury Research
Published on: November 3, 2023
Infrared Thermometer: an accurate tool for temperature measurement during renal surgery
Giovanni Scala Marchini1, Ricardo Jordão Duarte, Anuar Ibrahim Mitre
1Division of Urology, Clinics Hospital, University of Sao Paulo Medical School, SP, Brazil.
Purpose:
To evaluate infrared thermometer (IRT) accuracy compared to standard digital thermometer in measuring kidney temperature during arterial clamping with and without renal cooling.
Materials And Methods:
20 pigs weighting 20Kg underwent selective right renal arterial clamping, 10 with (Group 1 - Cold Ischemia with ice slush) and 10 without renal cooling (Group 2 - Warm Ischemia). Arterial clamping was performed without venous clamping. Renal temperature was serially measured following clamping of the main renal artery with the IRT and a digital contact thermometer (DT): immediate after clamping (T0), after 2 (T2), 5 (T5) and 10 minutes (T10). Temperature values were expressed in mean, standard deviation and range for each thermometer. We used the T student test to compare means and considered p < 0.05 to be statistically significant.
Results:
In Group 1, mean DT surface temperature decrease was 12.6 ± 4.1°C (5-19°C) while deep DT temperature decrease was 15.8 ± 1.5 °C (15-18 °C). For the IRT, mean temperature decrease was 9.1 ± 3.8 °C (3-14°C). There was no statistically significant difference between thermometers. In Group 2, surface temperature decrease for DT was 2.7 ± 1.8°C (0-4°C) and mean deep temperature decrease was 0.5 ± 1.0 °C (0-3 °C). For IRT, mean temperature decrease was 3.1 ± 1.9°C (0-6°C). No statistically significant difference between thermometers was found at any time point.
Conclusions:
IRT proved to be an accurate non-invasive precise device for renal temperature monitoring during kidney surgery. External ice slush cooling confirmed to be fast and effective at cooling the pig model.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Imaging Studies VII: Vascular Imaging
Imaging Studies II: Ultrasonography
