Related Experiment Video
Updated: May 7, 2026

Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
Selenium determination in biscuits and pasta: development of chronopotentiometric stripping determination by using a
Jaroslava Svarc-Gajić1, Zorica Stojanović
1Department of Applied and Engineering Chemistry, Faculty of Technology, University of Novi Sad, Novi Sad, Serbia.
Abstract:
Being common in chromatographic techniques internal standard method is rarely applied in electrochemical stripping determinations. One of the reasons for such rare use of this elegant quantification method is because optimal conditions of accumulation at the electrode for individual compounds producing a reproducible signal may vary significantly. These criteria are much stricter when selenium is in question due to very complex mechanism of its accumulation at mercury electrodes which implies simultaneous cathodic mercury dissolution and chemical reaction. Elements that are in the analytical step stripped cathodically from mercury electrodes are rare, further limiting the application of the internal standard method when electrochemical selenium determination is in question. In this work the possibility of using sulphide for selenium quantification by chronopotentiometric stripping analysis was investigated. Optimal experimental parameters were defined in two-component systems. Dimensionless factors defining the ratio of proportionality constants of the two elements were calculated for different selenium concentration ranges at different sulphide contents. Sulphide content that was chosen as adequate for selenium concentrations reasonably to be expected in food samples was 500 µg/dm(3). Determined detection limit of chronopotentiometric stripping determination of selenium by using a sulphide as an internal standard was 0.04 µg/dm(3) (RSD=7.6%; n=5). Defined quantification method was confirmed by analysing spiked standard solutions and standard reference material. The method was used for selenium determination in biscuit and pasta samples. Calculated contents were statistically compared with those obtained by using graphite furnace atomic absorption spectrometry.
More Related Videos
07:54Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
10:13Using Capillary Electrophoresis to Quantify Organic Acids from Plant Tissue: A Test Case Examining Coffea arabica Seeds
Published on: November 12, 2016