Evaluation of adsorbents for volatile methyl siloxanes sampling based on the determination of their breakthrough
1Université Lyon 1, CNRS, UMR 5256, IRCELYON, Institut de recherches sur la catalyse et l'environnement de Lyon, 2 avenue Albert Einstein, F-69626 Villeurbanne, France; Conseil National de la Recherche Scientifique, Commission Libanaise de l'Energie Atomique, Laboratoire d'analyse de Pesticides et de Polluants Organiques, B.P. 11-8282, Riad El Solh, 1107 2260 Beyrouth, Lebanon.
Abstract:
Volatile methyl siloxanes (VMS) have been detected in many different atmospheres such as biogas, sewage sludge, landfill gas, gasoline and ambient air. In these different atmospheres, their presence can involve several contamination problems and negative effects in industrial processes, their identification and quantification become a real challenge. Up to now there is no standardized procedure for VMS quantification, the sampling step remaining the major obstacle. Sampling gas through sorbent tube followed by analysis on TD-GC-MS is one of the reliable possibilities. It gathers sampling and preconcentration in one step and allows discrimination between all VMS, despite the difficulty to choose the appropriate adsorbent in order to avoid loss of analytes during sampling. In this context, this work deals with the comparison of different types of adsorbents based on the determination of the VMS breakthrough volume (BV). Although Tenax TA is the most widely used adsorbent, experiments show low BV values for the lightest VMS. At 25°C, the BV of TMS and L2 are, respectively, 0.2 and 0.44 L g(-1) which can contribute to an underestimation in concentration during their quantification. Carbosieve SIII usually used for C2-C5, did not adsorb light VMS as it was expected, and breakthrough volume obtained for VMS are more than ten times less than the values obtained for Tenax. On other hand, Chromosorb 106 and Carboxen 1000 in association with Carbotrap C and Carbotrap proved to be appropriated for VMS sampling, due to the high breakthrough volumes obtained for the lightest compounds comparing to the other adsorbents. The BVs of TMS for Carboxen 1000 and Chromosorb 106 are 1.2 × 10(4) and 39 L g(-1), respectively, and 49 × 10(4) and 1142 L g(-1) for L2, respectively.
Related Concept Videos
Volatilization
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Adsorption of Gases on Solids
Analyte Adsorption and Distribution