Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Noncontact mapping to guide ablation of right ventricular outflow tract arrhythmias
Fengxiang Zhang1, Bing Yang, Hongwu Chen
1Section of Pacing and Electrophysiology, Division of Cardiology, First Affiliated Hospital with Nanjing Medical University, Nanjing, People's Republic of China.
Background:
There is limited data on outcomes after noncontact mapping (NCM)-guided right ventricular outflow tract (RVOT) ventricular arrhythmia (VA) ablation.
Objectives:
To assess outcomes of NCM-guided RVOT VA ablation in a large cohort with extended follow-up, to determine optimal ablation site, and to analyze limitations of conventional mapping techniques.
Methods:
In consecutive patients undergoing RVOT VA ablation, 2 sites of early activation--earliest activation (EA) and breakout (BO) sites--were identified on NCM maps. Pace mapping and activation mapping were performed at both sites. The area of depolarized myocardium during the first 10 ms of spontaneous VA and pacing was measured. The initial site of ablation was randomized to either EA or BO sites, with crossover to the alternate site if ablation was not successful.
Results:
In 136 patients, prematurity of local activation and pace maps were similar at EA and BO sites. More myocardium was depolarized 10 ms after pacing than during spontaneous VA (12.9 ± 7.8 cm(2) vs 5.3 ± 3.9 cm(2); P < .01). Clinical success was more likely achieved when initial ablation was directed toward the EA site (P < .05). A wider EA-BO separation was associated with acute procedural failure (P < .01). With a follow-up of 36.2 ± 17.5 months, the success rate after a single procedure without antiarrhythmic agents was 86.8%.
Conclusions:
NCM-guided RVOT VA ablation is highly effective, and clinical success is best achieved by ablating the EA site. Broad regions of early activation are associated with worsened clinical outcomes. Spatial resolution of activation and pace mapping is limited by rapid electrical propagation in the RVOT.