Abstract:
A new generation of hollow waveguide (HWG) gas cells of unprecedented compact dimensions facilitating low sample volumes suitable for broad- and narrow-band mid-infrared (MIR; 2.5-20 μm) sensing applications is reported: the substrate-integrated hollow waveguide (iHWG). iHWGs are layered structures providing light guiding channels integrated into a solid-state substrate material, which are competitive if not superior in performance to conventional leaky-mode fiber optic silica HWGs having similar optical pathlengths. In particular, the provided flexibility in device and optical design and the wide variety of manufacturing strategies, substrate materials, access to the optical channel, and optical coating options highlight the advantages of iHWGs in terms of robustness, compactness, and cost-effectiveness. Finally, the unmatched modularity of this novel waveguide approach facilitates tailoring iHWGs to almost any kind of gas sensor technology providing adaptability to the specific demands of a wide range of sensing scenarios. Device fabrication is demonstrated for the example of a yin-yang-shaped gold-coated iHWG fabricated within an aluminum substrate with a footprint of only 75 mm × 50 mm × 12 mm (L × W × H), yet providing a nominal optical absorption path length of more than 22 cm. The analytical utility of this device for advanced MIR gas sensing applications is demonstrated for the gaseous constituents butane, carbon dioxide, cyclopropane, isobutylene, and methane.
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
IR Absorption Frequency: Hybridization
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that stretch at a...
IR Spectrometers