A Dynamic Electrode for the Estimation of Praseodymium(III) using 1,5-Bis-(o-aminophenol)-3-thiapentane as an

Acta Chimica Slovenica
|September 25, 2013
PubMed

Related Concept Videos

Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Potentiometry: Types of Electrodes01:19

Potentiometry: Types of Electrodes

Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
EDTA: Indirect and Alkalimetric Titration01:23

EDTA: Indirect and Alkalimetric Titration

Unlike direct titration, back-titration, and displacement titration, indirect titration is an EDTA titration method for quantifying anions. In the indirect titration method, anions are precipitated as their insoluble salts with excess metal ions. The filtrate containing the excess metal ions is directly titrated with standard EDTA until the endpoint is achieved. Another approach involves extracting the metal ion and back-titrating with standard EDTA to obtain the endpoint. In this way, the...
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)01:15

Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)

Insensitive Nuclei Enhanced by Polarization Transfer (INEPT) is an advanced Nuclear Magnetic Resonance (NMR) technique specifically designed to detect and enhance the signals of low-abundance nuclei, such as carbon-13 and nitrogen-15, in small molecules. The fundamental principle behind INEPT is the transfer of polarization from a more abundant and highly polarizable nucleus, typically hydrogen-1, to the low-abundance nucleus of interest. This process effectively boosts the NMR signal of the...
Electrodeposition01:08

Electrodeposition

Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...