Related Experiment Video
Updated: Apr 8, 2026

Implantation of a Carotid Cuff for Triggering Shear-stress Induced Atherosclerosis in Mice
Published on: January 13, 2012
Management of inadvertent carotid artery sheath insertion during central venous catheter placement
Carlos F Bechara1, Neal R Barshes, George Pisimisis
1Division of Vascular Surgery and Endovascular Therapy, Michael E. DeBakey Department of Surgery, Baylor College of Medicine, Houston, Texas2Michael E. DeBakey VA Medical Center, Houston, Texas.
Importance:
Inadvertent carotid sheath insertion during central venous catheter placement could lead to serious complications.
Objective:
To describe management of inadvertent carotid artery sheath insertion placed intraoperatively during attempted jugular venous cannulation for pulmonary artery catheter placement.
Design, Setting, And Participants:
In a retrospective medical record review of patients from hospitals affiliated with Baylor College of Medicine, Houston, Texas, a total of 12 patients over 11 years who sustained intraoperative carotid artery introducer sheath placement during attempted jugular vein cannulation were identified. Six patients underwent immediate carotid artery exploration with sheath removal and primary repair. The remaining 6 patients underwent percutaneous closure using a suture-mediated closure device. Treatment outcomes of these 2 groups were analyzed.
Main Outcomes And Measures:
Technical success, duration of treatment, stroke, return to the operating room, and long-term outcomes.
Results:
Technical success was achieved in all patients in both groups. The intended operations were aborted in all patients following catheter removal and carotid artery closure. The mean (SD) durations of treatment for the operative and endovascular groups were 32 (12) minutes and 6 (3) minutes, respectively (P = .03). No neurological deficit occurred in either group. The intended operations were all subsequently performed, and the mean delays of operation in the operative and endovascular groups were 5 and 3 days, respectively (P = .20). Follow-up carotid duplex showed no injury of the repaired artery in either group. During a mean follow-up of 42 months, no complications or neurological deficits were noted in either patient cohort.
Conclusions And Relevance:
Inadvertent carotid artery sheath placement during attempted central venous cannulation for pulmonary artery catheter insertion mandates catheter removal and repair of the carotid artery puncture site. The closure device permits percutaneous repair of the carotid artery expeditiously. Our experience showed this treatment modality to be as safe and effective as operative repair.
More Related Videos
08:41Carotid Artery Infusions for Pharmacokinetic and Pharmacodynamic Analysis of Taxanes in Mice
Published on: October 27, 2014
06:33Intubation, Central Venous Catheter, and Arterial Line Placement in Swine for Translational Research in Abdominal Transplantation Surgery
Published on: February 3, 2023
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization IV: Nursing Management
Aneurysm IV: Nursing Management
Venous Thrombosis III: Interprofessional Care