Related Experiment Video
Updated: May 7, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Hemodynamic profiles of intubated and mechanically ventilated carbon monoxide-poisoned patients during systemic
Marie-Ludivine Chateau-Degat1, Julien Poitras, Jacques H Abraini
1Hyperbaric Medicine and Gas Pharmacology Research Unit at the research center of the CSSS Alphonse Desjardins/CHAU de Lévis, Lévis, QC, Canada. ludivinechateaudegat@me.com.
Background:
Carbon monoxide (CO) poisoning can be a life threatening condition. Systemic hyperbaric oxygen (HBO) therapy is used to induce CO detoxification. However, little is known about the hemodynamic response to HBO in severely intoxicated patients.
Methods:
We retrospectively analyzed the medical records of 6 CO-poisoned patients treated with propofol, rocuronium bromide, and HBO. The HBO protocol comprised 3 HBO treatments (HBOT1 to HBOT3) within 24 hours. During all HBO sessions heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), and pulse blood pressure (ΔBP) were measured every five minutes. Non-parametric tests were used to compare data between HBO sessions.
Results:
HR increased significantly as the number of HBOT increased, from 68 beats per minute (bpm) during HBOT1 to 77 and 86 bpm during HBOT2 and HBOT3, respectively (p < 0.05). In addition, while no significant change was found for DBP, both SBP and ΔBP showed a transient and significant increase during HBOT2, compared to HBOT1, that did not return to basal values during HBOT3.
Conclusion:
Based on previous studies that have established the respective effects of rocuronium bromide, propofol, HBO, and CO alone on HR, SBP, and ΔBP, it is concluded that the hemodynamic responses observed in the present study are likely to be due to CO. If such, given that neither HR nor SBP and ΔBP returned to basal values by the end of HBOT3, it is suggested that more than 3 HBOT sessions could be necessary to provide full hemodynamic recovery in CO-poisoned patients.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Oxygen Transport in the Blood
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...