Gas velocity at the point of re-injection: an additional parameter in comprehensive two-dimensional gas
Peter Q Tranchida1, Mariosimone Zoccali, Flavio A Franchina
1Dipartimento di Scienze del Farmaco e dei Prodotti per la Salute, Università di Messina, viale Annunziata, 98168 Messina, Italy.
Abstract:
The present research is focused on the introduction of a new optimization parameter in the field of comprehensive 2D GC (GC×GC), herein defined as "gas velocity at the point of re-injection". GC×GC experiments were performed using a loop-type cryogenic modulator and a rapid-scanning quadrupole mass spectrometer, as detection system. All experiments were performed using a 30m×0.25mm ID apolar primary column, and a 1m×0.10mm ID medium-polarity secondary one. With regards to the modulator loops, three types of uncoated columns were used, namely with a 0.25, 0.18, and 0.10mm ID. It was found that under the same second-dimension analytical conditions (modulation, oven temperature, gas velocity) the quality of the GC×GC separation was dependent on the gas velocity at the moment of re-injection. For a loop-type modulator, the re-injection point is located at the downstream cooling/heating point of the delay loop. It was found that the GC×GC performance gradually improved when the ID of the modulator loop decreased (and the re-injection gas velocity increased), and reached its best when the 0.10mm ID uncoated column was used. GC×GC experiments were performed on a C14 n-alkane (to evaluate the efficiency of band re-injection, in terms of peak widths) and on an essential oil sample (to evaluate peak widths, resolution and the overall separation performance). The results herein reported are valid for practically any type of cryogenic modulator.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:22Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Elution Process