Related Experiment Video
Updated: May 7, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Diagnostic efficacy of PET and PET/CT for recurrent lung cancer: a meta-analysis
Yan-Qi He1, Han-Lin Gong, Yi-Fu Deng
1Department of Respiratory Medicine, West China Hospital of Sichuan University, Chengdu, PR China.
Background:
Lung cancer is one of the most common malignant tumors in the world, and is the leading cause of cancer-related mortality. Although there are no conclusive data to support the survival benefits of early detection or early treatment for recurrence, an early and accurate diagnosis of recurrence is critical to optimize therapy.
Purpose:
To compare the diagnostic value of positron emission tomography (PET) and positron emission tomography/computed tomography (PET/CT) using fluorine-18 deoxyglucose (18FDG) with conventional imaging techniques (CITs) for the detection of lung cancer recurrence.
Material And Methods:
A meta-analysis was performed, with systematic searches conducted using PubMed and EMBASE databases (up to 31 December 2011). Pooled sensitivity, specificity, and diagnostic odds ratio (DOR) values were calculated for 1035 patients reported in 13 articles. Summary receiver-operating characteristic curves (SROC) were also generated.
Results:
The pooled sensitivity (95% CI) for PET, PET/CT, and CITs were 0.94 (0.91-0.97), 0.90 (0.84-0.95), and 0.78 (0.71-0.84), respectively. The pooled specificity (95% CI) for PET, PET/CT, and CITs were 0.84 (0.77-0.89), 0.90 (0.87-0.93), and 0.80 (0.75-0.84), respectively. Regarding sensitivity, lower values were associated with CITs than PET (P = 0.000) and PET/CT (P = 0.005), and there was no significant difference between PET/CT and PET (P = 0.102). Regarding specificity, values for PET/CT and PET were significantly higher than for CITs (both P = 0.000), and there was no significant difference between PET/CT and PET (P = 0.273). In the SROC curves, a better diagnostic accuracy was associated with PET/CT than PET and CITs.
Conclusion:
PET/CT and PET were found to be superior modalities for the detection of recurrent lung cancer, and PET/CT was superior to PET.
More Related Videos
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care