Influence of light-curing units on the polymerization of low-shrinkage composite resins
Sang-Kyu Lee1, Tae-Wan Kim, Sung-Ae Son
1Department of Dental Materials, School of Dentistry and Medical Research Institute, Pusan National University.
Abstract:
This study examined the effect of various light-curing units (LCUs) on the polymerization of low-shrinkage composite resins. Two different types of low-shrinkage composite resins (silorane-based and methacrylate-based) were light cured using a quartz-tungsten-halogen (QTH) (HX) unit, a single-peak light-emitting diode (LED) (DM) unit, and a dual-peak LED (GL) unit, respectively. Among the tested LCUs, HX showed the lowest light attenuation within the specimens. Among the specimens, Aelite LS and Venus Diamond showed the highest and lowest light attenuation, respectively. Silorane-based Filtek LS showed the highest degree of conversion both on the top and bottom surfaces. On the bottom surface, Grandio and Aelite LS showed the lowest (4.5-7.1%) and highest (25.0-40.0%) decrease in the degree of conversion compared to their top surface. For different LCUs, within the same resin product, the microhardness was significantly different. The silorane-based composite resin showed significantly less polymerization shrinkage than the methacrylate-based nanofiller-containing composite resins.
Related Concept Videos
Accelerated Curing of Concrete
Curing of Concrete
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Curing Methods