Related Experiment Video
Updated: May 7, 2026

Positron Emission Tomography Using 64-Copper as a Tracer for the Study of Copper-Related Disorders
Published on: April 28, 2023
A study of technetium-99m wastage in selected private sector nuclear medicine imaging departments
Germaine Mathurine1, Philippa Bresser, Nadia Teixeira
1aDepartment of Radiography, Faculty of Health Sciences, University of Pretoria bDepartment of Nuclear Medicine, Little Company of Mary Hospital, Pretoria, South Africa.
Background:
South African nuclear medicine imaging departments have been fortunate in being able to receive an uninterrupted supply of molybdenum-99 (99Mo)/technetium-99m (99mTc) generators. Nuclear medicine radiographers practising in private sector services in the northern Gauteng region indicated a possible problem with the quantities of wasted and unused 99mTc radiopharmaceuticals returned to the radiopharmaceutical supply laboratory. Daily radiopharmaceutical deliveries are a combination of ordered packages and standard packages. The purpose of the standard package is to accommodate emergency and after-hours nuclear medicine services. The purpose of the study was to interrogate the unconfirmed reports of 99mTc radiopharmaceutical wastage.
Methods:
A descriptive quantitative research design was conducted in six private sector nuclear medicine imaging practices in the northern Gauteng region. Overt observations of the quantities of radiopharmaceutical supply, usage and wastage were conducted over 2 days in each of these practices.
Results:
Ordered packages comprised 14% of the total 99mTc radiopharmaceutical deliveries to these six nuclear medicine imaging departments. It was identified that:(1) a total of 83.2% of ordered packages and 35.1% of standard packages of preprepared syringes were utilized;(2) a total of 36% of ordered packages and 22.6% of standard packages of bulk 99mTc were utilized; and (3) a total of 70.6% of the total quantity of radiopharmaceuticals was returned to the radiopharmaceutical laboratory. The total wastage represented 45.5% of the ordered packages and 75.8% of the standard packages.
Conclusion:
Wastage of 74 GBq of 99mTc from six sites over 12 days should raise concerns for the nuclear medicine industry. A review of the system framework that supports communication between the radiopharmaceutical supplier/s and the nuclear medicine imaging practices is recommended.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
