Related Experiment Video
Updated: May 7, 2026

Engineering Molecular Recognition with Bio-mimetic Polymers on Single Walled Carbon Nanotubes
Published on: January 10, 2017
Design of a multiwalled carbon nanotube-Nafion-cysteamine modified tyrosinase biosensor and its adaptation of
1Department of Biochemistry, Faculty of Science, Ege University, 35100 Bornova, Izmir, Turkey.
Abstract:
In this work, a multiwalled carbon nanotube (MWCNT)-Nafion-cysteamine (CA) modified tyrosinase biosensor brings a new and original perspective to biosensor technology intended for the development of dopamine determination. Dopamine measurements were done at 0.2V with the amperometric method by the developed biosensor system. In addition, in this study dopamine determination was carried out by using the differential pulse voltammetry method between potentials of 0.4 and -0.15 V. In the optimization studies of the biosensor, some parameters such as optimal pH, optimal temperature, optimal enzyme amount, and effect of MWCNT concentration were investigated. Afterward, in the characterization studies, some parameters such as linearity and reproducibility were determined. In the reproducibility experiment, an average value of 1.026 μM, a standard deviation of ±0.03975, and a coefficient of variation of 3.8% were determined for a 1-μM dopamine concentration (n=15). Determination of dopamine was carried out in drug samples by the developed biosensor.