Related Experiment Video
Updated: May 7, 2026

Simultaneous pH Measurement in Endocytic and Cytosolic Compartments in Living Cells using Confocal Microscopy
Published on: April 28, 2014
A dynamic system for the simulation of fasting luminal pH-gradients using hydrogen carbonate buffers for dissolution
Grzegorz Garbacz1, Bartosz Kołodziej, Mirko Koziolek
1Physiolution GmbH, Walther-Rathenau-Straße 49 a, 17489 Greifswald, Germany.
Abstract:
The hydrogen carbonate buffer is considered as the most biorelevant buffer system for the simulation of intestinal conditions and covers the physiological pH range of the luminal fluids from pH 5.5 to about pH 8.4. The pH value of a hydrogen carbonate buffer is the result of a complex and dynamic interplay of the concentration of hydrogen carbonate ions, carbonic acid, the concentration of dissolved and solvated carbon dioxide and its partial pressure above the solution. The complex equilibrium between the different ions results in a thermodynamic instability of hydrogen carbonate solutions. In order to use hydrogen carbonate buffers with pH gradients in the physiological range and with the dynamics observed in vivo without changing the ionic strength of the solution, we developed a device (pHysio-grad®) that provides both acidification of the dissolution medium by microcomputer controlled carbon dioxide influx and alkalisation by degassing. This enables a continuous pH control and adjustment during dissolution of ionisable compounds. The results of the pH adjustment indicate that the system can compensate even rapid pH changes after addition of a basic or acidic moiety in amounts corresponding up to 90% of the overall buffer capacity. The results of the dissolution tests performed for a model formulation containing ionizable compounds (Nexium 20mg mups) indicate that both the simulated fasting intraluminal pH-profiles and the buffer species can significantly affect the dissolution process by changing the lag time prior to initial drug release and the release rate of the model compound. A prediction of the in vivo release behaviour of this formulation is thus most likely strongly related to the test conditions such as pH and buffer species.
More Related Videos
07:38Functional Characterization of Na+/H+ Exchangers of Intracellular Compartments Using Proton-killing Selection to Express Them at the Plasma Membrane
Published on: March 30, 2015
08:24Profiling Luminal pH in Three-Dimensional Gastrointestinal Organoids Using Microelectrodes
Published on: July 5, 2024
Related Concept Videos
Bicarbonate-Carbonic Acid Buffer
Buffer Systems in the Body
A typical buffer system in bodily fluids includes a weak acid and its corresponding anion,...
Phosphate Buffer
Sodium dihydrogen phosphate does not fully dissociate in neutral or acidic solutions. When a strong base, such as sodium hydroxide (NaOH), is introduced into the solution, sodium dihydrogen phosphate...
Calculating pH Changes in a Buffer Solution
Protein Buffers in Blood Plasma and Cells
Certain amino acids can exist in a zwitterion state at a...
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...