Assessment of aortic valve opening during rotary blood pump support using pump signals
Marcus Granegger1, Heinrich Schima, Daniel Zimpfer
1Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; Ludwig-Boltzmann-Cluster for Cardiovascular Research, Vienna, Austria.
Abstract:
During left ventricular support by rotary blood pumps (RBPs), the biomechanics of the aortic valve (AV) are altered, potentially leading to adverse events like commissural fusion, valve insufficiency, or thrombus formation. To avoid these events, assessment of AV opening and consequent adaptation of pump speed seem important. Additionally, this information provides insight into the heart-pump interaction. The aim of this study was to develop a method to assess AV opening from the pump flow signal. Data from a numerical model of the cardiovascular system and animal experiments with an RBP were employed to detect the AV opening from the flow waveform under different hemodynamic conditions. Three features calculated from the pump flow waveform were used to classify the state of the AV: skewness, kurtosis, and crest factor. Three different classification algorithms were applied to determine the state of the AV based on these features. In the model data, the best classifier resulted in a percentage of correctly identified beats with a closed AV (specificity) of 99.9%. The percentage of correctly identified beats with an open AV (sensitivity) was 99.5%. In the animal experiments, specificity was 86.8% and sensitivity reached 96.5%. In conclusion, a method to detect AV opening independently from preload, afterload, heart rate, contractility, and degree of support was developed. This algorithm makes the evaluation of the state of the AV possible from pump data only, allowing pump speed adjustment for a frequent opening of the AV and providing information about the interaction of the native heart with the RBP.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Aortic Regurgitation I: Introduction
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.