Related Experiment Video
Updated: May 7, 2026

Scaling of Engineered Vascular Grafts Using 3D Printed Guides and the Ring Stacking Method
Published on: March 27, 2017
First human use of an allogeneic tissue-engineered vascular graft for hemodialysis access
Wojciech Wystrychowski1, Todd N McAllister2, Krzysztof Zagalski1
1Department of General, Vascular, and Transplant Surgery, Medical University of Silesia, Katowice, Poland.
Abstract:
An arteriovenous fistula is the current gold standard for chronic hemodialysis access. Tunneled catheters or synthetic grafts have poorer outcomes and much higher risks of infection. This report presents the first clinical use of a completely biological, allogeneic, nonliving, and human tissue-engineered vascular graft. Tissue-engineered vascular grafts built from allogeneic fibroblasts were implanted as shunts in three hemodialysis patients. The tissue-engineered vascular graft was stored for 9 months, without loss of mechanical strength. Implanted grafts showed no signs of degradation or dilation, with time points up to 11 months. Results of panel-reactive antibody and cross-reactivity tests showed no evidence of immune responses.
Related Concept Videos
Hemodialysis I: Introduction
Hemodialysis II: Procedure and Complications