Surface tension of airway aspirates withdrawn during neonatal resuscitation reflects lung maturity
Guido Stichtenoth1, Gabi Walter, Romy Lange
1Department of Pediatrics, University of Luebeck, Luebeck, Germany.
Abstract:
The indications for treatment of neonates with exogenous pulmonary surfactant are still discussed controversially. Some premature neonates are sufficiently treated by CPAP, others need conventional ventilation and/or surfactant. The available lung maturity tests have limitations. The captive bubble surfactometer (CBS) provides measurement of surface activity from rather small amounts of surfactant. This study aimed to determine surface activity from small volume aspirates of the upper airways of neonates by means of the CBS and to correlate the results with clinical data. Small upper airway aspirates from 159 neonates (gestational age 25-42 weeks) were withdrawn and concentrated 16.7-fold by ultracentrifugation and resuspension in saline. Surface activities after 5 min of adsorption were determined in the CBS and correlated to the perinatal data (e.g., gestational age, birth weight, gender), airway interventions (like CPAP, conventional ventilation) and surfactant treatment. Additionally, 27 samples were analyzed for surfactant specific phosphatidylcholine concentrations by using electrospray ionization tandem mass-spectroscopy. Surface activities show a significant correlation to gestational age, birth weight, and the need for airway interventions. Comparing the need for airway interventions versus surface activity, a receiver operating characteristic calculated a sensitivity of 0.77 and a specificity of 0.72 at a "cut off" of 44 mN/m. Surface activity correlates significantly with the phosphatidylcholine concentrations and the latter one correlates with the gestational age. Determination of surface activity from upper airway aspirates is feasible. Further clinical studies are needed to prove the predictive value of the method.
Related Concept Videos
Breathing
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Pulmonary Cycle: Exhalation
Suctioning the Nasopharyngeal Airway
Equipment Required