Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Electrodeposition01:08

Electrodeposition

2.8K
Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
2.8K
Colloidal precipitates01:09

Colloidal precipitates

5.7K
The high insolubility of some precipitates can result in an unfavorable relative supersaturation. This can lead to colloidal particles with a large surface-to-mass ratio, where adsorption is promoted. For instance, in the precipitation of silver chloride, silver ions are adsorbed on the surface of the colloidal particles, forming a primary layer. This layer attracts ions of opposite charge (such as nitrate ions), forming a diffuse secondary layer of adsorbed ions. This electric double layer...
5.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Hybrid biofabrication of multilayered 3D neuronal networks with structural and functional interlayer connectivity.

Biosensors & bioelectronics·2025
Same author

A 3D neuronal network read-out interface with high recording performance using a neuronal cluster patterning on a microelectrode array.

Biosensors & bioelectronics·2024
Same author

Connectivity and network burst properties of in-vitro neuronal networks induced by a clustered structure with alginate hydrogel patterning.

Biomedical engineering letters·2023
Same author

Enhancement of Thermoplasmonic Neural Modulation Using a Gold Nanorod-Immobilized Polydopamine Film.

ACS applied materials & interfaces·2022
Same author

Optical recording of neural responses to gold-nanorod mediated photothermal neural inhibition.

Journal of neuroscience methods·2022
Same author

Neurons-on-a-Chip: <i>In Vitro</i> NeuroTools.

Molecules and cells·2022

Related Experiment Video

Updated: May 7, 2026

Electrochemical Roughening of Thin-Film Platinum Macro and Microelectrodes
08:32

Electrochemical Roughening of Thin-Film Platinum Macro and Microelectrodes

Published on: June 30, 2019

7.4K

Novel platinum black electroplating technique improving mechanical stability.

Raeyoung Kim, Yoonkey Nam

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |October 11, 2013
    PubMed
    Summary
    This summary is machine-generated.

    Mechanically stable platinum black microelectrodes were developed using polydopamine to enhance neural signal recording. This modification prevents performance degradation from physical stimuli, extending sensor availability.

    More Related Videos

    Localized Bathless Metal-Composite Plating via Electrostamping
    08:05

    Localized Bathless Metal-Composite Plating via Electrostamping

    Published on: September 22, 2020

    3.8K
    Synthesis of Platinum-nickel Nanowires and Optimization for Oxygen Reduction Performance
    09:02

    Synthesis of Platinum-nickel Nanowires and Optimization for Oxygen Reduction Performance

    Published on: April 27, 2018

    7.4K

    Related Experiment Videos

    Last Updated: May 7, 2026

    Electrochemical Roughening of Thin-Film Platinum Macro and Microelectrodes
    08:32

    Electrochemical Roughening of Thin-Film Platinum Macro and Microelectrodes

    Published on: June 30, 2019

    7.4K
    Localized Bathless Metal-Composite Plating via Electrostamping
    08:05

    Localized Bathless Metal-Composite Plating via Electrostamping

    Published on: September 22, 2020

    3.8K
    Synthesis of Platinum-nickel Nanowires and Optimization for Oxygen Reduction Performance
    09:02

    Synthesis of Platinum-nickel Nanowires and Optimization for Oxygen Reduction Performance

    Published on: April 27, 2018

    7.4K

    Area of Science:

    • Biomaterials Engineering
    • Neuroscience
    • Materials Science

    Background:

    • Platinum black microelectrodes are vital for neural signal recording due to their fabrication simplicity, signal quality, and biocompatibility.
    • The porous structure of conventional platinum black microelectrodes is susceptible to damage from physical stimuli encountered in biological systems.
    • Damage to microelectrodes leads to increased impedance and diminished neural recording performance.

    Purpose of the Study:

    • To develop mechanically robust platinum black microelectrodes.
    • To enhance the durability and long-term performance of neural recording sensors.
    • To investigate the stabilizing effect of polydopamine on platinum black microelectrode structures.

    Main Methods:

    • Incorporation of a polydopamine layer between platinum black structures via electrodeposition.
    • Fabrication of both standard platinum black microelectrodes and polydopamine-modified microelectrodes.
    • Assessment of microelectrode stability and impedance changes under mechanical stress (ultrasonication).

    Main Results:

    • Polydopamine-added microelectrodes exhibited significantly greater mechanical stability compared to platinum black-only electrodes.
    • Ultrasonication caused a dramatic impedance increase in platinum black-only electrodes, while polydopamine-added electrodes showed minimal impedance rise.
    • Initial impedance levels were comparable between the two electrode types, highlighting the specific enhancement of mechanical robustness.

    Conclusions:

    • Polydopamine modification effectively enhances the mechanical stability of platinum black microelectrodes.
    • The developed microelectrodes maintain stable impedance under physical stress, crucial for reliable neural recording.
    • Polydopamine-added platinum black microelectrodes show promise for extended use as durable neural sensors.