Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research
Published on: January 12, 2013
Analysis of the rotational center location method in Optical Projection Tomography
Abstract:
In Optical Projection Tomography (OPT), if the rotational center deviates from the central line of the image and this offset is not corrected during the reconstruction, serious blurring will happen in the final 3-dimensional (3D) result. Therefore, the high-precision rotational center location method is very important for OPT. However, existing methods are inconvenient because they need active participation during the location process. Thus, the automated and fast rotational center location method is in great demand. In preliminary work, we proposed an automated rotational center location method which consisted of a high Specimen Signal Intensity (SSI) sinogram selection and a coarse-fine search. Our method had an accuracy of about 1/4 pixel. However, further robustness analysis of our method is lacking. In this paper, we have investigated its location errors on sinograms with various SSIs and analyzed whether it was effective to use high SSI sinograms for rotational center location. Moreover, we have also discussed the relationship between location errors and the starting rotational angles. The experimental results showed that our coarse-fine method was robust under different starting angles. Meanwhile, the high SSI sinogram selection scheme improved the location precision.
More Related Videos
Related Concept Videos
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Centroid for the Paraboloid of Revolution
The centroid for the paraboloid of revolution is the point where all the mass of the paraboloid is concentrated. This centroid is important for engineering applications, as it determines how forces are...
Imaging Studies III: Computed Tomography
Rotational Motion about a Fixed Axis