Development and testing of an artificial arterial and venous pulse oximeter
Abstract:
The monitoring of patients healthcare is of a prime importance to ensure their efficient and effective treatment. Monitoring blood oxygen saturation is a field which has grown significantly in recent times and more specifically in tissues affected by diseases or conditions that may negatively affect the function of the tissue. This study involved the development and testing of a highly sensitive non-invasive blood oxygen saturation monitoring device. A device that can be used to continuously monitor the condition of tissue affected by diseases which affect the blood flow through the tissue, and the oxygen usage in tissue. The device's system was designed to specifically monitor occluded tissue which has low oxygen saturations and low perfusion. Although with limitted validation the system was unable to accurately measure the venous oxygenation specifically, but it was able to measure the mixed oxygen saturation. With further research it would be possible to validate the system for measuring both the arterial and venous oxygen saturations.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse
The pulse serves as a clinical...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation