Comparative analysis of two systems for unobtrusive heart signal acquisition and characterization
Abstract:
In this paper we describe and compared method of heart rate estimation from cardiac signal acquired with EMFIT, FMCW Doppler radar and Finapres based technology, in the same context, and briefly investigated their similarities and differences. Study of processing of acquired cardiac signal for accurate peak detection using Wavelet Transform is also described. The results suggest good reliability of the two implemented unobtrusive systems for heart rate estimation.
Related Concept Videos
Pulse rhythm
1.7K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.7K
Equipments Used To Measure Blood Pressure
3.4K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.4K
Correlation between ECG and Cardiac Cycle
13.7K
The electrical signals recorded on an electrocardiogram (ECG) occur before the mechanical processes of contraction and relaxation during the cardiac cycle.
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
13.7K
Special considerations while measuring pulse
1.0K
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
1.0K
Imaging Studies for Cardiovascular System I:Echocardiography
1.0K
Cardiac imaging studies encompass a wide range of noninvasive and minimally invasive techniques designed to visualize the heart's structure and function in detail. One such technique is echocardiography, which uses high-frequency ultrasound waves to produce detailed images of the heart, known as echocardiograms.
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
1.0K