External quality assessment in molecular immunohematology: the INSTAND proficiency test program
Willy A Flegel1, Ion Chiosea, Ulrich J Sachs
1Department of Transfusion Medicine, NIH Clinical Center, National Institutes of Health, Bethesda, Maryland.
External quality assessments (EQAs) for red blood cell (RBC), platelet (PLT), and granulocyte antigen genotyping show high participation and pass rates. However, there has been minimal improvement in molecular immunohematology testing performance since 2006.
Area of Science:
- Molecular immunohematology
- Transfusion medicine
- Clinical pathology
Background:
- Genotyping for red blood cell (RBC), platelet (PLT), and granulocyte antigens is a critical tool for transfusion medicine and blood banks.
- External quality assessments (EQAs) are essential for establishing laboratory test proficiency and clinical application.
- Limited EQAs are available for molecular immunohematology.
Purpose of the Study:
- To analyze participation and pass rates in an established EQA for RBC, PLT, and granulocyte antigens.
- To evaluate the trends in molecular immunohematology testing performance over time.
Main Methods:
- Analysis of participation and pass rates in INSTAND's EQA Number 235 Immunohematology A (molecular diagnostic) from Fall 2006 to Fall 2012.
- Tracking of participant numbers, system participation (RBC, PLT, granulocytes), and allele detection rates.
- Assessment of pass rates for specific antigen systems, including RHD and ABO.
Main Results:
- Participant numbers increased steadily, with over 60 institutions utilizing the EQA annually.
- High participation rates were observed for RBC (approx. 80%) and PLT (approx. 68%) systems, with lower participation in granulocyte systems (approx. 22%).
- Pass rates generally exceeded 93%, with exceptions for RHD (82%) and granulocytes (85%); pass rates showed minor changes over 6.5 years, with an increase for granulocytes and a decrease for ABO.
Conclusions:
- The INSTAND proficiency testing program is widely adopted, particularly in Central Europe, for molecular immunohematology EQAs.
- Participating laboratories demonstrate high technical standards and consistent pass rates.
- Despite high performance, there has been limited improvement in pass rates for molecular immunohematology testing since the program's inception in 2006.
More Related Videos
08:04Development of an IFN-γ ELISpot Assay to Assess Varicella-Zoster Virus-specific Cell-mediated Immunity Following Umbilical Cord Blood Transplantation
Published on: July 9, 2014
07:57Quantification of Protein Interaction Network Dynamics using Multiplexed Co-Immunoprecipitation
Published on: August 21, 2019
Related Concept Videos
Automated Microbial Diagnostics
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...