Nonadditivity of forward and simultaneous masking

Adam Svec1, Suyash N Joshi, Walt Jesteadt

  • 1Center for Hearing Research, Boys Town National Research Hospital, 555 N. 30th Street, Omaha, Nebraska 68131.

Summary

Additional masking, a measure of auditory perception, increases with masker level and signal delay. Findings challenge its use in understanding basilar membrane compression and simulating hearing loss.

Related Concept Videos

Masking and Demasking Agents01:19

Masking and Demasking Agents

EDTA titrations may necessitate masking and demasking agents to temporarily protect a particular metal ion in a mixture from the EDTA reaction. These agents facilitate the sequential analysis of the metal ions by forming stable complexes with some—but not all—metal ions during certain steps.
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
4.1K
Interference and Superposition of Waves01:07

Interference and Superposition of Waves

When two waves of the same nature occur in the same region simultaneously, they result in interference. Interference of waves implies that the net effect of the waves is the sum of the individual waves' effects. However, it does not imply that the individual waves affect the propagation of other waves.
Interference occurs in mechanical waves, such as sound waves, waves on a string, and surface water waves. Mechanical waves correspond to the physical displacement of particles. Hence,...
5.8K
Pharmacodynamic Models: Additive and Proportional Drug Effect Model01:09

Pharmacodynamic Models: Additive and Proportional Drug Effect Model

Drug response models describe how pharmacological agents interact with biological systems to produce measurable effects. Baseline responses are inherent physiological activities without a drug significantly influencing the observed pharmacological outcomes. Depending on the drug response model employed, these baseline responses may combine with the drug's effect in either an additive or proportional manner.Additive Drug Response ModelIn the additive model, the drug effect is independent of the...
122
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model01:13

Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model

Drugs administered through various routes can lead to nonlinear elimination, resulting in complex pharmacokinetic behaviors crucial to understanding efficacious drug dosing.
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
429
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
9.2K
Convolution Properties I01:20

Convolution Properties I

Convolution computations can be simplified by utilizing their inherent properties.
The commutative property reveals that the input and the impulse response of an LTI (Linear Time-Invariant) system can be interchanged without affecting the output:
778