Related Experiment Video
Updated: May 7, 2026

Pore-scale Imaging and Characterization of Hydrocarbon Reservoir Rock Wettability at Subsurface Conditions Using X-ray Microtomography
Published on: October 21, 2018
Interpreting a pumping test influenced by another well in an anisotropic aquifer
Simon Weber1, Robert P Chapuis, François Duhaime
1Department of Civil, Geological and Mining Engineering, Ecole Polytechnique, P.O. Box 6079, Stn CV, Montreal, Quebec, Canada H3C 3A7.
Abstract:
In confined aquifers the influence of neighboring active wells is often neglected when interpreting a pumping test. This can, however, lead to an erroneous interpretation of the pumping test data. This article presents simple methods to evaluate the transmissivity tensor and storativity of an anisotropic confined aquifer when there is an interfering well in the neighborhood of the tested well. Two methods have been developed depending on whether the tested well or the interfering well is the first in operation. These new methods yield better estimates of the hydraulic parameters than when the influence of the interfering well is neglected. These methods have then been used on data obtained from numerical models with an interfering well and the results have been compared to an analytical method that neglects the influence of the interfering well. The methods require knowledge of the pumping rate of the interfering well and the time elapsed since the pumping started in each well. If the interfering well started pumping before the tested well, the method does not require knowledge of the aquifer piezometric level at the beginning of the test, which is often unknown in this case. As for the method without interference, at least three monitoring wells (MWs) are needed, the position of which influences the accuracy of the estimated parameters. Some recommendations concerning MWs position have been given to get more accurate results according to the sought parameter.
Related Concept Videos
Application of the Energy Equation
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...

