Flow dynamics of different adult ECMO systems: a clinical evaluation
Karla Lehle1, Alois Philipp, Thomas Müller
1Department of Cardiothoracic Surgery, University Medical Center Regensburg, Regensburg, Germany.
Abstract:
Membrane oxygenator (MO) failure is a known hazard during venovenous extracorporeal membrane oxygenation (v-v ECMO) therapy. Knowledge about technical and performance details of different ECMO systems (Maquet, Rastatt, Germany; Medos, Stolberg, Germany; Sorin, Modena, Italy) licensed for adults with acute lung failure might improve their handling. This retrospective study comprises 186 adult patients (Regensburg ECMO Registry) treated with v-v ECMO. Flow dynamic data were used to analyze the performance of different blood pumps, cannula types, and MOs to maintain an adequate blood flow (1-5 L/min). Usage of the Medos ECMO system in critically ill patients required a higher pump speed and generated a higher pressure drop across the MO (dpMO), however, without an increase in free plasma hemoglobin. The dpMO depended on the type of MO and increased with blood flow as expected. Type-specific normal values are reported. A distinct increase in dpMO above normal values within 1 day required an immediate MO exchange. This was an infrequent technical complication (3%). Finally, pressure-flow performance of single dual-lumen cannulas (27 Fr) was comparable with small single-lumen cannulas (15 Fr), without an increased risk of technical-induced hemolysis. Despite different performances, all current commercially available adult v-v ECMO systems produce adequate blood flow without an increased risk in technical-induced hemolysis. Familiarity with the specific properties of individual systems allows early detection of technical complications. Additionally, the choice of an adequate cannula requires a closer consideration of the individual patient situation.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...