Aims And Objectives:
To determine the time dependent accuracy of casts made from three different irreversible hydrocolloids.
Materials And Methods:
The effect of delayed pouring on the accuracy of three different irreversible hydrocolloid impression materials - Regular set CA 37(Cavex, The Netherlands), regular set chromatic (Jeltrate, Dentsply), and fast set (Hydrogum soft, Zhermack Clinical) was investigated. A brass master die that contained two identical posts simulating two complete crown-tapered abutment preparations with reference grooves served as a standardized master model. A total of 120 impressions were made using specially prepared stock-perforated brass tray with 40 impressions of each material. The impressions were further sub-grouped according to four different storage time intervals: 0 min (immediately), 12 min, 30 min, and 1 h. The impressions were stored at room temperature in a zip-lock plastic bag. Interabutment and intraabutment distances were measured in the recovered stone dies (Type IV, Kalrock) using a profile projector with an accuracy of 0.001 mm. The data so obtained was analyzed statistically.
Results:
Results of this study showed no statistically significant differences in the accuracy of casts obtained at different time intervals.
Conclusion:
Because it is not always possible to pour the impression immediately in routine clinical practice, all irreversible hydrocolloid materials studied could be stored in a zip-lock plastic bag for upto 1 h without any significant distortion.
More Related Videos
09:22Casting Protocols for the Production of Open Cell Aluminum Foams by the Replication Technique and the Effect on Porosity
Published on: December 11, 2014
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Related Concept Videos
Setting Time of Cement
Testing Water Quality
Porosity in Cement Paste
The balance of water to cement in the mix is...
Pore Size Distribution
Adequate...
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the...