Related Experiment Video
Updated: May 7, 2026

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Vinylbenzyl quaternary ammonium-based polymeric monolith with hydrophilic interaction/strong anion exchange
Xucong Lin1, Shuhui Feng, Wenchao Jia
1Institute of Food Safety and Environmental Monitoring, Fuzhou University, Fuzhou 350108, China.
Abstract:
A novel polymeric monolith with hydrophilic interaction and strong anion-exchange mixed-mode has been fabricated for pressurized capillary electrochromatography by an in situ copolymerization of vinylbenzyl trimethylammonium chloride (VBTA) and bisphenol A glycerolate dimethacrylate (BisGMA). The optimization of the polymerization mixture composition has been investigated, and column characteristics in terms of mechanical stability, permeability and reproducibility have been studied in detail. Linear responses between back pressure and flow rate have been achieved in different solvents. The absolute value of swelling propensity (SP) factor for poly(VBTA-co-BisGMA) monolith is 0.41, and the degree of permeability drop from pure ACN to water is about 45%. An acceptable mechanical stability of the column is obtained. The suitable reproducibility is also measured with the RSD for day-to-day (n=3) of retention time and column efficiency less than 3.3%, and the RSD for batch-to-batch (n=3) less than 5.3%, respectively. Under the optimum conditions, the mixed-mode of hydrophilic interaction and strong anion-exchange has been carried out, and efficient electrochromatography profiling of various polar compounds including neutral phenols, negatively charged benzoic acids and positively charged nucleic acid bases and nucleosides are achieved, respectively.
More Related Videos
10:27Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
07:32Preparation and Characterization of Individual and Multi-drug Loaded Physically Entrapped Polymeric Micelles
Published on: August 28, 2015
Related Concept Videos
Ion Exchange
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Types Of Column Chromatography
Gel Filtration Chromatography
When the...