Related Experiment Video
Updated: May 6, 2026

A Duplex Digital PCR Assay for Simultaneous Quantification of the Enterococcus spp. and the Human Fecal-associated HF183 Marker in Waters
Published on: March 9, 2016
A new dual plasmid calibrator for the quantification of the construct specific GM canola Oxy-235 with duplex
Maher Chaouachi1, Ahmed Ben Hafsa, Nesrine Nabi
1Laboratoire de Génétique, Biodiversité et Valorisation des Bioressources, Institut Supérieur de Biotechnologie de Monastir, Université de Monastir, Avenue Tahar Haddad, 5000, BP74, Monastir, Tunisia.
Abstract:
To overcome the difficulties of obtaining the Certified Reference Material (CRM) and according to the key documents of the European Union Reference Laboratory (EU-RL), a new standard reference molecule containing the construct specific of the canola event Oxy-235 (3'-junction Nitrilase/Tnos) and the canola endogenous reference gene (acety-CoA-carboxylase) was constructed and used for duplex real-time quantitative analysis. The limits of detection (LOD) were less than 5 Haploid Genome Copy (HGC) and the limits of quantification (LOQ) were about 10 HGC. Furthermore, mixed GM and non-GM canola samples were analysed with duplex QRT-PCR to evaluate the performance criteria as required for validation procedures in the EU-RL, namely, the precision and the accuracy. The accuracy expressed as bias ranged from 2% to 10% and the precision (repeatability and reproducibility) expressed as the RSDr and RSDR was from 2.2 to 5.12 and 2.15 to 5.46 respectively. All these indicated that the developed construct specific method and the reference molecule are suitable for the identification and the quantification of the canola event Oxy-235.