Related Experiment Video
Updated: May 6, 2026

Fabrication of Magnetic Nanostructures on Silicon Nitride Membranes for Magnetic Vortex Studies Using Transmission Microscopy Techniques
Published on: July 2, 2018
Vortex beam production and contrast enhancement from a magnetic spiral phase plate
1Hitachi Cambridge Laboratory, Cavendish Laboratory, J. J. Thomson Ave., Cambridge CB3 0HE, United Kingdom.
Abstract:
Electron vortex beam probes offer the possibility of mapping magnetic moments with atomic resolution. In this work we consider using the stray magnetic field produced from a narrow ferromagnetic rod magnetised along its long axis to produce a vortex beam probe, as an alternative to the currently used holographic apertures or gratings. We show through numerical modelling, electron holography observations and direct imaging of the electron probe, that a long narrow ferromagnetic rod induces a phase shift in the wave-function of passing electrons that approximately describes a helix in the regions near its ends. Directing this rod towards the optical axis of a charged-particle beam probe forming system at a limiting aperture position, with the free-end sufficiently close to the axis, is shown to offer a point spread function composed of vortex modes, with evidence of this appearing in observations of the electron probe formed from inserting a micro-fabricated CoFe rod into the beam path of a 300 keV transmission electron microscope (TEM). If the rod is arranged to contain the magnetic flux of h/e, thus producing a maximum phase shift of 2π, it produces a simple spiral-like phase contrast transfer function for weak phase objects. In this arrangement the ferromagnetic rod can be used as a phase plate, positioned at the objective aperture position of a TEM, yielding enhanced image contrast which is simulated to be intermediate between comparable Zernike and Hilbert phase plates. Though this aspect of the phase plate performance is not demonstrated here, agreement between our observations and models for the probe formed from an example rod containing a magnetic flux of ~2.35h/e, indicate this phase plate arrangement could be a simple means of enhancing contrast and gaining additional information from TEM imaged weak phase samples, while also offering the capability to produce vortex beam probes. However, steps still need to be taken to either remove or improve the support membrane for the rod in our experiments to reduce any effects from charging in the phase plate.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
Steady, Laminar Flow Between Parallel Plates
Magnetic Field Lines
Magnetic field lines follow several hard-and-fast rules:
Divergence and Curl of Magnetic Field
Magnetic Field Of A Current Loop