Related Experiment Video
Updated: Feb 9, 2026

Establishment and Evaluation of a Porcine Vein Graft Disease Model
Published on: July 25, 2022
Surgery for acquired cardiovascular disease: antiseptic treatment of contaminated vein grafts
F P Schmidt1, A A Peivandi, W Kohnen
1Second Medical Department University Medical Center Johannes Gutenberg University, Mainz, Germany - bjansen@uni-mainz.de.
Aim:
Saphenous vein grafts harvested for use as bypass conduits can be contaminated intraoperatively, e.g. by being inadvertently dropped to the floor of the operating room (OR). This study was performed to investigate microorganisms most likely contaminating vein grafts and to assess the possible efficacy of measures to treat potentially contaminated vein grafts antiseptically for further use.
Methods:
In a first step we determined the microbiological flora of the OR using surface cultures and cultures from intentionally dropped vein grafts. Several antiseptic agents (PVP-iodine 10%, octenidinhydrochloride 0.1%, polyhexanide 1%) were evaluated for their in vitro efficacy to disinfect artificially contaminated vein segments. The most promising antiseptic regimen was tested on veins contaminated in a real OR setting. Finally, we tested for possible alterations in mechanical properties of the veins caused by antiseptic treatment.
Results:
Coagulase-negative staphylococci where the predominant bacteria recovered from the OR with 59.9%. Antiseptic treatment with a combination of octenidine and PVP-iodine resulted in a higher rate of negative cultures than any single agent. Treatment of 50 saphenous vein grafts contaminated in the OR with the combination regimen resulted in only 3 positive cultural results within 7 days. Mechanical tear-stress testing comparing antiseptically treated vein grafts with controls showed no difference in their resistance to tear stress.
Conclusion:
Antiseptic treatment of contaminated vein grafts was shown to be effective in a high percentage of cases without altering mechanical properties of grafts and may be an option for the surgeon in case of a contamination.
Insights
Contaminated saphenous vein grafts can be effectively disinfected using a combination of octenidine and PVP-iodine. This antiseptic treatment ensures graft viability without compromising mechanical properties, offering a viable option for intraoperative contamination.
Area of Science:
- Microbiology
- Vascular Surgery
- Biomaterials Science
Background:
- Saphenous vein grafts are crucial bypass conduits in cardiovascular surgery.
- Intraoperative contamination of vein grafts, such as dropping them in the operating room (OR), poses a significant risk.
- Effective decontamination strategies are needed to ensure graft safety and usability.
Purpose of the Study:
- To identify the predominant microorganisms contaminating vein grafts in the OR.
- To evaluate the efficacy of various antiseptic agents in disinfecting contaminated vein segments.
- To assess the impact of antiseptic treatment on the mechanical properties of vein grafts.
Main Methods:
- Surface and graft cultures were used to determine OR microbiological flora.
- In vitro efficacy of PVP-iodine, octenidine, and polyhexanide was assessed.
- A combination regimen was tested on real-world contaminated grafts, followed by mechanical tear-stress testing.
Main Results:
- Coagulase-negative staphylococci were the most common contaminants (59.9%).
- A combination of octenidine and PVP-iodine yielded a higher rate of negative cultures than single agents.
- Antiseptic treatment of 50 contaminated grafts resulted in only 3 positive cultures within 7 days, with no significant alteration in mechanical properties.
Conclusions:
- Antiseptic treatment with octenidine and PVP-iodine effectively decontaminates saphenous vein grafts.
- This treatment preserves the mechanical integrity of the grafts.
- It presents a potentially valuable option for surgeons managing intraoperative graft contamination.
More Related Videos
Related Concept Videos
Psychoneuroimmunology: Cardiovascular Disease
A key area of focus in PNI is the relationship between stress and coronary...
Parkinson's Disease: Treatment
Parkinson's Disease is primarily a result of the loss of dopaminergic neurons in the substantia nigra pars compacta. The cornerstone of...
Alzheimer's Disease: Treatment
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Drugs for Treatment of Crohn's Disease in IBD Using Glucocorticoids
Overview of the Cardiovascular System
Heart
The heart is the central pump of the cardiovascular system that circulates blood throughout the body. It comprises two atria receiving the blood and two ventricles pumping blood out of the heart. Their rhythmic contractions, called heartbeats, ensure that blood flow remains continuous.
Blood Vessels
Blood...